| Customization: | Available |
|---|---|
| Application: | High-performance Transducer, Three Phase Transducer, General Transducer, High Frequency Converter Transducer |
| Output Type: | Triple |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
| Item | Specification | |
| Input | Rated voltage | T4: Three phase 380V, ±15% S/T2: Single phase or Three phase 220V, ±15% |
| Frequency | 50/60Hz ±5% | |
| Output | Voltage | T4: Three phase 0~380V S/T2: Single phase or Three phase 0~220V |
| Frequency | 0~3000Hz | |
| Overload ability | 150% rated current for30s 180% rated current for 1s |
|
| Radiating | Cooling type | Forced cooling |
| Temperature protection | It trips over heat protection when the radiator temperature is higher than 85 degrees. | |
| Fan control | It operates in drive running. | |
| Control Performance | Control mode | Open-loop vector control, V/F control |
| Start torque | Open-loop vector control:0.5Hz 180%, VF control:0.5Hz 150% |
|
| Speed adjustment range | Open-loop vector control: 1:150 VF control: 1:100 |
|
| Speed control precision | Open-loop vector control: ±0.2% VF control: ±0.5% |
|
| Function | Run command channel | Keyboard control, Terminal control , Communication control |
| Start Mode | Direct start, Dc brake first and then start, Speed tracking and then start |
|
| DC Brake | Start DC brake, Stop DC brake | |
| Dynamic brake | Built-in brake unit | |
| Frequency source selection | Keyboard digital frequency set, analog V1 set, keyboard potentiometer set, PID control set, communication set | |
| Master and auxiliary frequency combination setting | Select the master frequency set or auxiliary frequency set by switching terminals | |
| Frequency resolution | Keyboard Setting : 0.01Hz,Analog setting: 0.1% | |
| Carrier frequency | 0.75KHz~15KHz (The upper carrier limit is limited by the drive model) | |
| Acceleration and deceleration time | 0.1~3200.0s | |
| Built-in PID | Built -in PID controller,it has the sleep wake function, which can achieve the maximum energy saving at the same time | |
| Common function | Fault Auto-recovery, PID voltage regulator function, jump frequency, UP/DOWN control, automatic voltage regulator AVR, over-voltage stall protection, over-loss speed protection, etc. | |
| Input and output signals | Analog Input | 1. Input Range: DC 0V~10V/4mA~20mA,it is decided by JP1 jumper selection on control board. 2.Input Resistance: voltage input 22kΩ, current input 500Ω. |
| Analog output | The voltage or current output is determined by the JP2 jumper selection on the control board. Output voltage range: 0V~10V Output current range: 0mA~20mA |
|
| Digital input | S1~S6 6 programmable multi-function input | |
| Communication Interface | Communication Protocol | Based on RS485 hardware, it supports standard MODBUS protocol |
| Display function | Five digit digital tube display | The operation status of the drive can be monitored flexibly and conveniently |
| protection function | Various protection functions | Including overvoltage, over-current, overheat, overload, under-voltage, short circuit, protect the ac drive running reliably all-round. |
| Installation Environment Requirement |
Ambient temperature | -10~40ºC(ambient temperature is within 40ºC, derating use is required), not allow to contact direct sunlight. |
| Humidity | Less than 90% RH, without condensation | |
| Application environment | Non-corrosive, flammable, explosive, dust absorbent material, all kinds of lint does not Accumulate. | |
| Vibration | Less than0.6G | |
| Elevation | 0~1000m, reduce the rated specification 10% when lift 1000m for each. | |
| Structure | Protection level, vibration |
IP20 |

